ECP4111T-4 Baldor Three Phase, Totally Enclosed, Foot Mounted 25HP, 1180RPM, 324T Frame UPC #781568107393
Part #ECP4111T-4 Baldor Three Phase, Totally Enclosed, Foot Mounted 25HP, 1180RPM, 324T Frame.
Special Price
$8,478.75
was
$9,500.00
SKU
ECP4111T-4-781568107393
ECP4111T-4 Baldor Three Phase, Totally Enclosed, Foot Mounted 25HP, 1180RPM, 324T Frame UPC #781568107393 is available to buy in increments of 1
Baldor Three Phase, Totally Enclosed, Foot Mounted 25HP, 1180RPM, 324T Frame
Features
- Robust cast iron construction
- Regreasable bearings all frames
- IP55, IP54 on 5000 frame and larger
- Embossed raised letter, 304 stainless steel nameplates
- Inverter ready nameplate
- Division 2, Class I, Groups A,B,C,D markings on nameplate
Applications
- Chemical, Oil & Gas
- Pulp & Paper, Forest Products
- Metals & Foundries
- Cement, Aggregate & above ground Mining
- Food Processing
- Power Generation
Specification
Output | 25 hp | KVA Code | H | |
Phase | 3 | Lifting Lugs | Standard Lifting Lugs | |
Synchronous Speed | 1200 rpm | Locked Bearing Indicator | Locked Bearing | |
Frequency | 60 Hz | Max Speed | 1800 rpm | |
Voltage | 460 V | Motor Lead Exit | KO Box | |
Frame Material | Iron | Motor Lead Quantity/Wire Size | 3 @ 8 AWG | |
Frame | 324T | Motor Lead Termination | Flying Leads | |
XP Class and Group | NONE | Motor Standards | NEMA | |
XP Division | Division II | Motor Type | 1260M | |
Brand | Baldor-Reliance | Number of Poles | 6 | |
Agency Approvals | CSA CSA EEV UR |
Overall Length | 30.27 in | |
Ambient Temperature | 40 °C | Power Factor | 79 | |
Auxillary Box | No Auxillary Box | Product Family | Super-E Chemical Processing | |
Auxillary Box Lead Termination | None | Pulley End Bearing Type | Ball | |
Base Indicator | Rigid | Pulley Face Code | Standard | |
Bearing Grease Type | POLYREX EM (-20F +300F) | Pulley Shaft Indicator | Standard | |
Blower | None | Rodent Screen | None | |
Constant Torque Speed Range | 1.0 | Service Factor | 1.15 | |
Current | 32.0 A | Shaft Diameter | 2.125 in | |
Design Code | A | Shaft Extension Location | Pulley End | |
Drip Cover | No Drip Cover | Shaft Ground Indicator | No Shaft Grounding | |
Duty Rating | CONT | Shaft Rotation | Reversible | |
Efficiency @ 100% Load | 93.0% | Shaft Slinger Indicator | Shaft Slinger | |
Electrically Isolated Bearing | Not Electrically Isolated | Speed | 1180 rpm | |
Feedback Device | No feedback | Speed Code | Single Speed | |
Front Face Code | Standard | Starting Method | Direct on line | |
Front Shaft Indicator | None | Thermal Device - Bearing | None | |
Heater Indicator | No heater | Thermal Device - Winding | None | |
High Voltage Full Load Amps | 32.0 A | Vibration Sensor Indicator | No Vibration Sensor | |
Insulation Class | F | Winding Thermal 1 | None | |
Inverter Code | Inverter duty | Winding Thermal 2 |
None | |
XP Temp Code | T3 |
NamePlate
CAT.NO. | ECP4111T-4 | P/N | ENCLOSURE | TEFC | |||||||
SPEC. | 12F904Y447 | CC | 010A | FRAME | 324T | S/N | |||||
HP | 25 | CLASS | F | HZ | 60 | DES | A | ||||
RPM | 1180 | RPM MAX | 1800 | PH | 3 | KVA-CODE | H | ||||
VOLT | 460 | MOTOR WEIGHT | 605 | ||||||||
AMP | 32 | SER.F. | 1.15 | PF | 79 | ODE BRG | 6312 | DE BRG | 6312 | ||
RATING | 40C AMB-CONT | NEMA-NOM-EFF | 93 | GREASE | POLYREX EM | ||||||
INV.TYPE |
PWM |
||||||||||
TEMP CODE | T3 | INVERTER-TEMP-CODE | 200 | ||||||||
TEMP = | 200 | C HP FR | 60 | C HP TO | 90 | ||||||
CT HZ FROM | 1.0 | CT HZ TO | 60 | ||||||||
HTR-VOLTS | HTR-AMPS | HTR-WATTS | MAX. SPACE HEATER TEMP. | VT HZ FROM | 3 | VT HZ TO | 60 |
NP3241
Part Number | Description | Quantity | List Price |
09FN3001B03SP | EXTERNAL FAN, PLASTIC | 1.000 EA | 65.00 USD |
MN416A01 | TAG-INSTAL-MAINT no wire (1000/bx) 11/14 | 1.000 EA | 0.04 USD |
***Please Note: Item Photos above are for General Reference and may not always be exact. Please see the product description and quick overview section for complete listing of item details and any additional components and specifications***
Product Availability | Ships within 24 to 48 hours |
---|---|
Manufacturer | Baldor |
Output | 25 hp |
Speed | 1200 rpm |
Phase | Three Phase |
Frequency | 60 Hz |
Frame | 324T |
Motor Type | 1260M |
Efficiencies @ 100% Load | 93% |
High Voltage Full Load Amps (FLA) | 32 A |
Service Factor | 1.15 |
Number of Poles | 6 |
Motor Voltage | 460V |
Write Your Own Review
More from Baldor
-
ECP84111T-4 Baldor Three Phase, Totally Enclosed, IEEE 841, 25HP, 1180RPM, 324T Frame UPC #781568210703Special Price $9,388.21 was $10,519.00
-
ECP84107T-4 Baldor Three Phase, Totally Enclosed, IEEE 841, 25HP, 3520RPM, 284TS Frame UPC #781568211076Special Price $6,417.97 was $7,191.00
-
ECP84103T-4 Baldor Three Phase, Totally Enclosed, IEEE 841, 25HP, 1770RPM, 284T Frame UPC #781568196625Special Price $5,931.56 was $6,646.00
-
ECP84109T-4 Baldor Three Phase, Totally Enclosed, IEEE 841, 40HP, 3540RPM, 324TS Frame UPC #781568210437Special Price $10,518.11 was $11,785.00
-
ECP84104T-4 Baldor Three Phase, Totally Enclosed, IEEE 841, 30HP, 1770RPM, 286T Frame UPC #781568196632Special Price $6,984.71 was $7,826.00
-
ECP84108T-4 Baldor Three Phase, Totally Enclosed, IEEE 841, 30HP, 3525RPM, 286TS Frame UPC #781568211083Special Price $7,688.00 was $8,614.00
-
ECP84117T-4 Baldor Three Phase, Totally Enclosed, IEEE 841, 30HP, 1180RPM, 326T Frame UPC #781568210697Special Price $12,217.43 was $13,689.00