Note: Requires 20 cfm at 80 psi shop air pressure at the pump. dBA 85/90 at 10,000 psi.
* Holds pressure in advance position when valve motor is shut off or in return position with motor running. Pump will build pressure when motor is shut off and oil returns to reservoir.
NOTE: Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17.
Order No.
A (in.)
B (in.)
C (in.)
D (in.)
E (in.)
F (in.)
H (in.)
Max Pressure Output (psi)
Oil Del. * (cu. in/min. @)
0 (psi)
100 (psi)
1,000 (psi)
1,500 (psi)
10,000 (psi)
PA172
14 1/8
11 3/8
9 1/4
7
7 1/8
5 1/8
3/8 NPTF
10,000
290
240
24
23
17
* Typical delivery. Actual flow will vary with field conditions.