ECP2401T-4 Baldor Three Phase, Totally Enclosed, Foot Mounted 7 1/2HP, 880RPM, 256T Frame UPC #781568463468
Part #ECP2401T-4 Baldor Three Phase, Totally Enclosed, Foot Mounted 7 1/2HP, 880RPM, 256T Frame.
Special Price
$7,033.79
was
$7,881.00
SKU
ECP2401T-4-781568463468
ECP2401T-4 Baldor Three Phase, Totally Enclosed, Foot Mounted 7 1/2HP, 880RPM, 256T Frame UPC #781568463468 is available to buy in increments of 1
Baldor Three Phase, Totally Enclosed, Foot Mounted 7 1/2HP, 880RPM, 256T Frame
Features
- Robust cast iron construction
- Regreasable bearings all frames
- IP55, IP54 on 5000 frame and larger
- Embossed raised letter, 304 stainless steel nameplates
- Inverter ready nameplate
- Division 2, Class I, Groups A,B,C,D markings on nameplate
Applications
- Chemical, Oil & Gas
- Pulp & Paper, Forest Products
- Metals & Foundries
- Cement, Aggregate & above ground Mining
- Food Processing
- Power Generation
Specification
Output | 7 1/2 hp | KVA Code | J | |
Phase | 3 | Lifting Lugs | Standard Lifting Lugs | |
Synchronous Speed | 900 rpm | Locked Bearing Indicator | Locked Bearing | |
Frequency | 60 Hz | Max Speed | 1325 rpm | |
Voltage | 460 V | Motor Lead Exit | KO Box | |
Frame Material | Iron | Motor Lead Quantity/Wire Size | 3 @ 12 AWG | |
Frame | 256T | Motor Lead Termination | Flying Leads | |
XP Class and Group | NONE | Motor Standards | NEMA | |
XP Division | Division II | Motor Type | 0960M | |
Brand | Baldor-Reliance | Number of Poles | 8 | |
Agency Approvals | CSA CSA EEV UR |
Overall Length | 24.78 in | |
Ambient Temperature | 40 °C | Power Factor | 67 | |
Auxillary Box | No Auxillary Box | Product Family | Super-E Chemical Processing | |
Auxillary Box Lead Termination | None | Pulley End Bearing Type | Ball | |
Base Indicator | Rigid | Pulley Face Code | Standard | |
Bearing Grease Type | POLYREX EM (-20F +300F) | Pulley Shaft Indicator | Standard | |
Blower | None | Rodent Screen | None | |
Constant Torque Speed Range | 1.3 | Service Factor | 1.15 | |
Current | 12.2 A | Shaft Diameter | 1.625 in | |
Design Code | A | Shaft Extension Location | Pulley End | |
Drip Cover | No Drip Cover | Shaft Ground Indicator | No Shaft Grounding | |
Duty Rating | CONT | Shaft Rotation | Reversible | |
Efficiency @ 100% Load | 86.5% | Shaft Slinger Indicator | Shaft Slinger | |
Electrically Isolated Bearing | Not Electrically Isolated | Speed | 880 rpm | |
Feedback Device | No feedback | Speed Code | Single Speed | |
Front Face Code | Standard | Starting Method | Direct on line | |
Front Shaft Indicator | None | Thermal Device - Bearing | None | |
Heater Indicator | No heater | Thermal Device - Winding | None | |
High Voltage Full Load Amps | 12.2 A | Vibration Sensor Indicator | No Vibration Sensor | |
Insulation Class | F | Winding Thermal 1 | None | |
Inverter Code | Inverter duty | Winding Thermal 2 |
None | |
XP Temp Code | T3C |
NamePlate
CAT.NO. | ECP2401T-4 | P/N | ENCLOSURE | TEFC | |||||||
SPEC. | 09J371Z703 | CC | 010A | FRAME | 256T | S/N | |||||
HP | 7.5 | CLASS | F | HZ | 60 | DES | A | ||||
RPM | 880 | RPM MAX | 1325 | PH | 3 | KVA-CODE | J | ||||
VOLT | 460 | MOTOR WEIGHT | 347 | ||||||||
AMP | 12.2 | SER.F. | 1.15 | PF | 67 | ODE BRG | 6309 | DE BRG | 6309 | ||
RATING | 40C AMB-CONT | NEMA-NOM-EFF | 86.5 | GREASE | POLYREX EM | ||||||
INV.TYPE |
PWM |
||||||||||
TEMP CODE | T3C | INVERTER-TEMP-CODE | 200 | ||||||||
TEMP = | 160 | C HP FR | 60 | C HP TO | 90 | ||||||
CT HZ FROM | 1.3 | CT HZ TO | 60 | ||||||||
HTR-VOLTS | HTR-AMPS | HTR-WATTS | MAX. SPACE HEATER TEMP. | VT HZ FROM | O | VT HZ TO | 60 |
NP3241
Part Number | Description | Quantity | List Price |
MN416A01 | TAG-INSTAL-MAINT no wire (1000/bx) 11/14 | 1.000 EA | 0.04 USD |
***Please Note: Item Photos above are for General Reference and may not always be exact. Please see the product description and quick overview section for complete listing of item details and any additional components and specifications***
Product Availability | Ships within 24 to 48 hours |
---|---|
Manufacturer | Baldor |
Output | 7 1/2 hp |
Speed | 900 rpm |
Phase | Three Phase |
Frequency | 60 Hz |
Frame | 256T |
Motor Type | 0960M |
Efficiencies @ 100% Load | 86.5% |
High Voltage Full Load Amps (FLA) | 12.2 A |
Service Factor | 1.15 |
Number of Poles | 8 |
Motor Voltage | 460V |
Write Your Own Review
More from Baldor
-
EM2539T-5 Baldor Three Phase, Open Drip Proof, Foot Mounted 40HP, 1770RPM, 324T Frame UPC #781568118764Special Price $6,636.63 was $7,436.00
-
EM2535T-5 Baldor Three Phase, Open Drip Proof, Foot Mounted 30HP, 1775RPM, 286T Frame UPC #781568118740Special Price $5,088.14 was $5,701.00
-
EM2547T-5 Baldor Three Phase, Open Drip Proof, Foot Mounted 60HP, 1775RPM, 364T Frame UPC #781568118801Special Price $9,220.42 was $10,331.00
-
EM2551T-5 Baldor Three Phase, Open Drip Proof, Foot Mounted 75HP, 1775RPM, 365T Frame UPC #781568542095Special Price $11,317.79 was $12,681.00
-
EM2559T-5 Baldor Three Phase, Open Drip Proof, Foot Mounted 125HP, 1775RPM, 405T Frame UPC #781568541593Special Price $16,153.36 was $18,099.00
-
EM2555T-5 Baldor Three Phase, Open Drip Proof, Foot Mounted 100HP, 1780RPM, 404T Frame UPC #781568542897Special Price $13,166.16 was $14,752.00
-
EM2543T-5 Baldor Three Phase, Open Drip Proof, Foot Mounted 50HP, 1775RPM, 326T Frame UPC #781568118788Special Price $7,322.96 was $8,205.00