9502 SPX Power Team 3-Way, 3-Position Non-Interflow Manual UPC #662536127509

9502 SPX Power Team 3-Way, 3-Position Non-Interflow Manual UPC #662536127509

9506 SPX Power Team 4-Way, 3-Position (Tandem Center) Valve With Posi-Check UPC #662536127547

9506 SPX Power Team 4-Way, 3-Position (Tandem Center) Valve With Posi-Check UPC #662536127547

9504 SPX Power Team 3/4-way, 2-position Manual UPC #662536127523

Part #9504 SPX Power Team 3/4-way, 2-position Manual, 4.2 lbs
Special Price $590.96 was $664.00
SKU
9504-662536127523

SPX Power Team 3/4-way, 2-position Manual:

Application – Single or double-acting cylinders.

Actuation – Lever operated, detent positioned.

Functions – Pos. 1 – Oil is directed to “advance” side of cylinder, oil from “retract” side goes to reservoir; cylinder “holds” with pump shut off. Pos. 2 – Oil goes to “retract” side of cylinder; cylinder “holds” with pump shut off. When using as a 3-way valve for single-acting cylinders, port “A” or “B” is plugged.

Used on these pumps – P460, PA6D, PA17, PA46, PA55, PA60, PE17, PE21, PE30, PE46, PE55, PE84, PE90, PE120, PE200, PE400, PQ60 and PQ120 series.

NOTE: 9504 can be remote mounted with a 9510 Subplates.

NOTE: A Pressure Switch and/or Gauge (Analog or Digital) may be attached to this valve.

CAUTION: To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.

IMPORTANT: Conversion kit 251528 must be used when mounting any of the valves on PA17 or PE17 pumps.

IMPORTANT: When ordering any valve for a PE30 or PG30 series pump, ½” longer mounting screws are required.
For valves 9504, 9584, 9610 and 9610A, order four 12001 cap screws.
For valve 9582, order two 12001 and two 10856 cap screws.

NOTE: Valves 9501, 9502, 9504 and 9507 can have a port blocked or have a closed center position. When a port is blocked and the valve is shifted to the blocked port, the pump will generate excessive heat. An electric or rotary air pump can either be turned off manually or with a pressure switch. Reciprocating air pumps may be adjusted to stall out and stop.

NOTE: Gauge ports monitor pump pressure only, not pressure to the hydraulic cylinder(s).

Order No.Cylinder
Application *
OperationValve TypeVoltAdvance / ReturnAdvance / Hold ReturnPosi-Check FeatureWeight (lbs.)
9504 S.A. & D.A. Manual 3/4-way, 2 Pos. Yes Yes No 4.2


* “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders



***Please Note: Item Photos above are for General Reference and may not always be exact. Please see the product description and quick overview section for complete listing of item details and any additional components and specifications***

More Information
Product Availability In Stock
Manufacturer SPX Power Team
Write Your Own Review
You're reviewing:9504 SPX Power Team 3/4-way, 2-position Manual UPC #662536127523