71214TN2ST00N0C111P3 Parker Skinner 2 Way Normally Closed 1/4

71214TN2ST00N0C111P3 Parker Skinner 2 Way Normally Closed 1/4" NPT Direct Acting Teflon Solenoid Valve 110/50-120/60VAC Conduit

71214TN2ST00N0D100P3 Parker Skinner 2 Way Normally Closed 1/4

71214TN2ST00N0D100P3 Parker Skinner 2 Way Normally Closed 1/4" NPT Direct Acting Teflon Solenoid Valve 110/50-120/60VAC DIN

71214TN2ST00N0C111Q3 Parker Skinner 2 Way Normally Closed 1/4" NPT Direct Acting Teflon Solenoid Valve 220/50-240/60VAC Conduit

Part # 71214TN2ST00N0C111Q3 Parker Skinner 2 Way Normally Closed 1/4" NPT Direct Acting Teflon Solenoid Valve 220/50-240/60VAC Conduit

Special Price $450.45 was $536.25
SKU
71214TN2ST00N0C111Q3
71214TN2ST00N0C111Q3 Parker Skinner 2 Way Normally Closed 1/4" NPT Direct Acting Teflon Solenoid Valve 220/50-240/60VAC Conduit is available to buy in increments of 1

71214TN2ST00N0C111Q3 Parker Skinner 2 Way Normally Closed 1/4" NPT Direct Acting Teflon Solenoid Valve 220/50-240/60VAC Conduit

Port Size NPTOrifice Size in.Cv FactorOperating Pressure Differential (PSI)Max. Fluid Temp. °FPressure Vessel NumberReference
Min.Maximum
AC RatingsDC RatingsCoilValve
10 Watt10 Watt
1/43/160.470202014071214TN2ST007D7

3 Way Manual Reset solenoid valves are designed to start and stop the flow of media as the result of an electrical signal. This can be a problem in some power outage situations were the valve must remain in the no voltage supplied position until the system is manually restarted. Manual reset valves have an added safety device to address this issue. When the manual reset device is triggered, the valve remains in the at rest position until the reset mechanism is manually latched.

Pilot operated versions require minimum operating pressure differential for proper operation.

Installation

Valves can be mounted in any position.

Mechanical Characteristics

  • Standard Materials of Construction
  • Body—brass or stainless steel (430)
  • Seals—NBR or FKM seals as listed
  • Sleeve tube—stainless steel (303 or 304)
  • Plunger—stainless steel (430FR)
  • Shading ring—copper
  • Stop—stainless steel (430FR)
  • Springs—stainless steel (18-8)
  • Pilot orifice—stainless steel (303)

Compatible Fluids

  • Depending on the valve used, most common media including air, inert gases or petroleum products.
  • Hydraulic Fluids

Power Consumption

10, 22 watts

Agency Approvals

cUL listed.

Applications:

  • Pilot control on process valves
  • Fluid “circuit breakers” requiring manual intervention to reset after being tripped (safety feature).



***Please Note: Item Photos above are for General Reference and may not always be exact. Please see the product description and quick overview section for complete listing of item details and any additional components and specifications***

More Information
UPC 71214TN2ST00N0C111Q3
Valve Series Parker Skinner 7000
Valve Actuation Direct Acting
Valve Functional Type 2 Way
Valve Flow Patterns Normally Closed
Valve Body Material Teflon
Valve Port Size 1/4" NPT
Valve Orifice Size 3/16"
Solenoid Valve Pressure AC $20.00
Valve Seal Type PTFE / Teflon
Coil Voltage 220/50-240/60 AC
Coil Type Conduit
Coil Enclosures Nut and Washer
Product Availability Ships within 20 working days (4 weeks)
Manufacturer Parker Skinner
Write Your Own Review
You're reviewing:71214TN2ST00N0C111Q3 Parker Skinner 2 Way Normally Closed 1/4" NPT Direct Acting Teflon Solenoid Valve 220/50-240/60VAC Conduit
More from Parker Skinner